Algorithm Type:
Case, Control
Institution:
Implementation Details:
- The case definition is unclear in the algorithm.
- Here we reported PPV for the case defined as results from chest x-array report (NLP).
- If the case is defined by both ICD and x-array report, then the PPV is 100%. The number of case is 156.
- If the case is defined by ICD, x-array report and ABX, then the PPV is 100%. The number of case is 2.
- The control defined in this study is unclear as well. There are control A, control B, and controlAB. Here we reported PPV for all controls (three groups).
- The overall impression is the negation NLP is not accurate which leads to the high error rate.
Phenotype:
Cases (156) | Actual Class (Expectation) | |
Predicted Class (Observation) |
True Positive: 100.00 |
Unexpected result |
Control (8015) | Actual Class (Expectation) | |
Predicted Class (Observation) |
True Positive: 0.96 |
False Positive: 0.04 |
Control Positive Predictive Value:
96%
|
Comments
review results and data
review results and data dictionary uploaded.
algorithm updated
algorithm updated